6.2.4. The electromagnetic locking valve - general information, removal and installation
|
Try not to allow hits of dirt in TNVD! |
General information
Protective cap of the contact socket of the electromagnetic locking valve (TNVD Bosch) |
Removal of a protective cap of the contact socket of the electromagnetic locking valve (TNVD Lucas)
|
The valve is located TNVD end face. The valve serves for trim of supply of fuel at switching off of ignition. At disconnection of the valve or break of a wire of its food start of the engine becomes impossible as fuel simply will not come to nozzles. Besides to result provides jamming of a plunger of the valve in the provision "is locked". If the valve jams in situation "openly", the engine stop after switching off of ignition will not occur. |
At failure of the locking valve temporary start of the engine can be made by removal of the valve (see below), extraction of a plunger from it with a spring and installations into place without internal components. The wire should be wound so that it did not adjoin to weight. To kill the engine after such start it is necessary to use the lever of a manual stop on TNVD (see the Power supply system - diesel models), or to switch off ignition on transfer.
Removal
PERFORMANCE ORDER |
|
|
Installation
Installation is made upside-down. Do not forget to replace a sealing washer / ring of the valve. Track respect for the required effort of tightening.
If the detachment of a driving cable of bystry idling was made, execute its adjustment (see Removal, installation and adjustment of the thermosensitive RPM meter of bystry idling).