6f6d7d92



7.1.6. Removal and installation of the generator

Removal

 PERFORMANCE ORDER

1. Disconnect a negative wire from the battery.
2. Weaken a belt of the drive of auxiliary units (address the Head Routine maintenance) and throw off it from a generator pulley.

3. At the corresponding complete set remove protective rubber caps from generator plugs, then release terminal nuts and disconnect an electrical wiring from a back part of the generator.

4. Give a bolt/nut of fastening of the generator to the top basic arm. Pay attention that if for fastening of the generator the long through bolt is used, then there is no need for its full reversing: will be to weaken it only enough. On some models for the purpose of ensuring access to fixture of the generator it is necessary to remove an intermediate pulley / a tension roller of a driving belt.

5. On diesel models take clamps of fastening of the filter of a cover and remove the last for the purpose of ensuring access to the top fixing bolt.

6. Remove the generator from basic arms and take it from a motive compartment.

Installation